AUMA SA 07.2/SA 16.2/SAR 07.2/SAR 16.2 AUMATIC AC 01.2 Actuator Control Unit Operating Manual
This manual covers AUMA SA 07.2, SA 16.2, SAR 07.2 and SAR 16.2 multiturn actuators and the AUMATIC AC 01.2 intrusive control unit. It provides instructions for installation, commissioning, operation and maintenance of the electro-mechanical actuator and control unit.
The document includes safety information, identification, transport and storage, mounting, electrical connection, operation, position indication, signals, commissioning, troubleshooting, service, technical data, spare parts and certificates.
AUMA SA 16.2 specifications
| Torque setting range | 400 - 1000 Nm |
|---|---|
| Motor power | 5.0 kW |
| Rated voltage | 400 V 50 Hz 3-ph AC |
| Protection rating | IP68 |
| Operating temperature range | -25°C - +70°C |
Source: AUMA SA 16.2 AC 01.2 Rotary Actuator Technology Data Sheet
All AUMA SA 16.2 documents by type
Ratings, dimensions and ordering codes, for selection and design work.
Disassembly, diagnostics and part numbers, for repair.
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What is the rated power of the motor?
The motor has a rated power of 5.0 kW.
From: AUMA SA 16.2 AC 01.2 Rotary Actuator Technology Data Sheet
What is the torque adjustment range?
The torque can be adjusted between 400 Nm and 1000 Nm.
From: AUMA SA 16.2 AC 01.2 Rotary Actuator Technology Data Sheet
What output drive standards are supported?
The actuators support output drives according to EN ISO 5210, DIN 3210, and DIN 3338.
From: AUMA SA 07.2-SA 16.2 SAR 07.2-SAR 16.2 technology data
Are dimensions dependent on the motor used?
Yes, exact dimensions depend on the specific motor used.
From: AUMA SA 07.2-SA 16.2 SAR 07.2-SAR 16.2 technology data
What is the purpose of this manual?
This document contains information for installation, commissioning, operation, and maintenance personnel. It helps install and commission the equipment.
Which models does this manual cover?
It covers the SA 07.2–SA 16.2 and SAR 07.2–SAR 16.2 multi-turn actuator models with AUMATIC AC 01.2 intrusive control units.