AUMA SA 07.2-SA 16.2/SAR 07.2-SAR 16.2 Control Unit Operation Instructions
This document provides comprehensive operation instructions for AUMA multi-turn actuators (models SA 07.2 – SA 16.2/SAR 07.2 – SAR 16.2) equipped with the electromechanic control unit AC 01.2 Intrusive Profibus DP. It serves as a guide for installation, commissioning, operation, and maintenance staff, ensuring safe and correct usage of the device for industrial valves.
The manual details procedures for assembly, electrical connection, and menu navigation via push buttons. It includes specific instructions for setting bus addresses, torque switching, and limit positions, as well as troubleshooting fault indications and performing corrective actions. Technical data and spare parts lists are also provided.
AUMA SA 07.2 – SA 16.2/SAR 07.2 – SAR 16.2 specifications
| Application | Operation of industrial valves |
|---|---|
| Supported valve types | Globe valves, gate valves, butterfly valves, and ball valves |
| Enclosure protection for Ex zone 22 | IP68 |
| Dust hazardous location identification | II3D IP6X T150 °C |
| Maximum surface temperature in Ex zone 22 | +150 °C |
| Actuator controls | AUMA MATIC AM 01.1/AM 02.1 |
| Cable gland minimum protection for Ex zone 22 | IP67 |
| Standard version direction of rotation | Clockwise closing |
Source: AUMA SA 07.2 – SA 16.2/SAR 07.2 – SAR 16.2 Multi-turn Actuator Operation Instructions
All AUMA SA 07.2 – SA 16.2/SAR 07.2 – SAR 16.2 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
- AUMA SA 07.2 – SA 16.2/SAR 07.2 – SAR 16.2 Multi-turn Actuator Operation Instructions 72 p
- AUMA SA 07.2 – SA 16.2/SAR 07.2 – SAR 16.2 Multi-turn Actuators Installation and Operation Manual 72 p
- AUMA SA 07.2-SA 16.2/SAR 07.2-SAR 16.2 Control Unit Operation Instructions 80 p
- AUMA SA 07.2, SA 16.2, SAR 07.2, SAR 16.2 Operation Manual 48 p
- AUMA SA 07.2/SA 16.2/SAR 07.2/SAR 16.2 AUMATIC AC 01.2 Actuator Control Unit Operating Manual 76 p
Ratings, dimensions and ordering codes, for selection and design work.
Disassembly, diagnostics and part numbers, for repair.
Questions answered in these manuals
Which valve types are listed for AUMA multi-turn actuators?
Globe valves, gate valves, butterfly valves, and ball valves are listed.
From: AUMA SA 07.2 – SA 16.2/SAR 07.2 – SAR 16.2 Multi-turn Actuator Operation Instructions
What enclosure protection do the actuators meet for Ex zone 22?
The actuators are designed to meet enclosure protection IP68.
From: AUMA SA 07.2 – SA 16.2/SAR 07.2 – SAR 16.2 Multi-turn Actuator Operation Instructions
What is the control unit model for these actuators?
The control unit model is AM 01.1/AM 02.1.
From: AUMA SA 07.2 – SA 16.2/SAR 07.2 – SAR 16.2 Multi-turn Actuators Installation and Operation Manual
What is the product's model range?
The product model range is SA 07.2 – SA 16.2/SAR 07.2 – SAR 16.2.
From: AUMA SA 07.2 – SA 16.2/SAR 07.2 – SAR 16.2 Multi-turn Actuators Installation and Operation Manual
Who is authorized to perform assembly and maintenance?
Assembly, electrical connection, commissioning, operation, and maintenance must be carried out exclusively by suitably qualified personnel having been authorised by the end user or contractor.
From: AUMA SA 07.2-SA 16.2/SAR 07.2-SAR 16.2 Control Unit Operation Instructions
What are the prohibited applications for these actuators?
Prohibited applications include industrial trucks, lifting appliances, passenger lifts, roller conveyors, continuous operation, buried service, permanent submersion, and potentially explosive areas (except zone 22).
From: AUMA SA 07.2-SA 16.2/SAR 07.2-SAR 16.2 Control Unit Operation Instructions