Safety manual for the Vacon OPTBJ option board covering STO/SS1 functions, installation, wiring, and ATEX thermistor monitoring.
This document serves as a safety manual for the Vacon OPTBJ option board, which is used with Vacon 100 AC drives. It details the Safe Torque Off (STO) and Safe Stop 1 (SS1) safety functions, including technical data, wiring examples, and commissioning procedures. The manual also covers the thermistor function for ATEX compliance, explaining how the board monitors motor temperature to prevent overheating.
| STO Safety Integrity Level | SIL3 |
|---|---|
| STO Performance Level | PL"e" Category 3 |
| Overtemperature response time | 20ms |
| Overtemperature threshold | 4 kOhm |
| Thermistor input terminals | 28(TI1+) and 29(TI1-) |
The STO function complies with EN 61800-5-2 SIL3, EN ISO 13849-1 PL"e" Category 3, EN 62061: SILCL3, and IEC 61508: SIL3.
No, it is not allowed to perform any repair work on the OPTBJ board; faulty boards must be returned to Vacon for analysis.
Fault 29 (Atex thermistor) is activated, and the drive modulation is disabled within 20ms.