Installation guide for the QDSS mains switch option kit on Vacon 20 X drives, covering kit contents, cable routing, wiring to L1, L2, L3 and cover mounting.
This document describes how to install the mains switch option on a Vacon 20 X drive. It begins with the mounting instructions and lists the contents of the QDSS mains switch option spare kit for frame sizes MU2 and MU3, including the 40A NLT40 main switch assembly, the cover for the main switch, M4x14 screws and M5x23 screws.
The installation section walks through the work step by step: removing the cover from the drive, opening only the inlet holes needed for the cables, running the supply cable through the cable gland and terminal box, fixing the mains switch inside the drive, connecting the cables to line terminals L1, L2 and L3, fixing them with a cable clamp, connecting the ground wire, and finally mounting the plastic cover with its screws and the HMI cap.
| Main switch | 40A NLT40 assembly |
|---|---|
| QDSS option spare kit, MU2 | 60S01128 |
| QDSS option spare kit, MU3 | 60S01129 |
| M4x14 screws per kit | 2 |
| M5x23 screws, MU2 kit | 4 |
| M5x23 screws, MU3 kit | 6 |
| Line terminals | L1, L2, L3 |
The cables from the mains switch are connected to the line terminals L1, L2 and L3.
It is passed through the cable gland from the bottom side and then through the terminal box to the mains switch.
The MU3 QDSS option spare kit contains 6 M5x23 screws.
Mount the plastic cover onto the drive with its screws and the HMI cap.