Turck TN-Q80-H1147/C53 HF RFID read/write head technical data: 13.56 MHz, ISO 15693, 10…30 VDC, 146 mm read/write distance, IP67, for TBEN-* line topology.
The Turck TN-Q80-H1147/C53 is an HF RFID read/write head intended for bus line topology on TBEN-* modules. It works at an operating frequency of 13.56 MHz using inductive coupling conforming to ISO 15693 and NFC Typ 5, with a maximum read/write distance of 146 mm. Electrical data gives an operating voltage of 10…30 VDC, a nominal operating current of ≤ 80 mA and an inrush current of 1000 mA. The rectangular Q80 plastic housing (PBT-GF30-V0, yellow) measures 92 x 80 x 40 mm, is rated IP67 and is specified for an ambient temperature of -25…+70 °C.
The document states that the device can only be operated in a TBEN-S*-2RFID-* or TBEN-L*-4RFID-* line topology, with a maximum of 32 nodes per line and a maximum bus length of 50 m; a corresponding termination resistor is required and power is supplied only through the BL ident interface module. A type assignment table lists recommended and maximum read/write distances for various tags, and an accessories list covers termination resistors, T- and Y-splitters and BLident cables. This manual is written in Turkish.
| Operating voltage | 10…30 VDC |
|---|---|
| Nominal operating current | ≤ 80 mA |
| Inrush current | 1000 mA |
| RFID technology | HF RFID |
| Operating frequency | 13.56 MHz |
| Radio communication and protocol standards | ISO 15693, NFC Typ 5 |
| Read/write distance | max. 146 mm |
| Ambient temperature | -25…+70 °C |
| Dimensions | 92 x 80 x 40 mm |
| Housing material | Plastic, PBT-GF30-V0, yellow |
| Protection degree | IP67 |
| Shock resistance | 30 g (11 ms) |
| Vibration resistance | 55 Hz (1 mm) |
| MTTF | 248 years (SN 29500, Ed. 99, 40 °C) |
| Active field width | B80 mm |
| Approvals | CE, UKCA, FCC, UL, ACMA, RSM |
The maximum read/write distance is 146 mm. The document notes that specified distances are standard values measured under laboratory conditions.
It can only be operated in the line topology of a TBEN-S*-2RFID-* or TBEN-L*-4RFID-* module, and power is supplied only through the BL ident interface module.
A maximum of 32 nodes per line or connection is permitted, and the data bus may be up to 50 m long; the possible maximum length of the support line is 2 m.
It operates at an operating frequency of 13.56 MHz with inductive coupling, using the HF RFID technology.