Turck TB…-L…-4FDI-4FDX Safety I/O Module Safety Manual

This safety manual describes the safety characteristics and functions of the TB…-L…-4FDI-4FDX module.


Turck TB…-L…-4FDI-4FDX Safety I/O Module Safety Manual - cover page
Brand
TURCK
Category
Automation control Equipment
Document type
User Manual
Language
Spanish
Pages
43
File format
PDF
File size
2.4 MB
Published
17 November, 2023
Updated
17 November, 2023
MD5 checksum
6C9471498064BCFC9B2D3371DE4DC55A

About this manual

This safety manual covers the Turck TBPN-L…-4FDI-4FDX (PROFIsafe over PROFINET) and TBIP-L…-4FDI-4FDX (CIP Safety over EtherNet/IP) safety I/O block modules. It addresses functional safety according to EN ISO 13849-1 and IEC 61508 and contains the information required to operate the devices in functional safety systems.

The manual describes the devices' intended use, safety function, safety planning data, mounting, connection, addressing, web server configuration and operation, and includes wiring diagrams, switching examples, function tests, technical data and approvals. The modules provide four SIL3 safety inputs (FDI) and four freely usable SIL3 channels (FDX) as inputs or outputs, and are rated SIL3 per EN 61508 and EN 62061 and Category 4/PLe per EN ISO 13849-1. This manual is written in Spanish.

What's inside

  • About this manual
  • Safety instructions
  • Safety Integrity Level / Performance Level / Category
  • Product description
  • Safety function
  • Safety planning
  • Operating instructions
  • Wiring diagrams
  • Switching examples
  • Technical data

Specifications

Safety inputs (FDI)4 SIL3 safety inputs for 1- or 2-channel mechanical safety switches and electronic safety sensors (OSSD)
Configurable safety channels (FDX)4 SIL3 channels freely usable as inputs (FDI) or outputs (FDO)
Safety-related outputsFor safety-related shutdown of resistive loads up to 2 A
Safety ratingSIL3 per EN 61508 and EN 62061
Performance level / categoryCategory 4/PLe per EN ISO 13849-1
Temperature range-40 to +70 °C
Protection ratingIP67/IP69K
Pollution degreeMaximum pollution degree 2 in hazardous areas

Frequently asked questions

Which Turck safety modules does this manual apply to?

It applies to the PROFIsafe devices TBPN-L5-4FDI-4FDX and TBPN-LL-4FDI-4FDX and the CIP Safety devices TBIP-L4-4FDI-4FDX, TBIP-L5-4FDI-4FDX and TBIP-LL-4FDI-4FDX.

What safety level do the TB…-L…-4FDI-4FDX modules achieve?

The devices are classified for SIL3 per EN 61508 and EN 62061, and Category 4/PLe per EN ISO 13849-1.

Which output circuits may be used to release safety circuits?

Only the output circuits of connectors C4…C7 or X4…X7 may be used for releasing safety circuits per EN IEC 60204-1 and EN ISO 13850.