Turck …Y1… Magnetic Field Sensors Quick Start Guide

This guide introduces the features and use of the …Y1… series of magnetic field sensors.


Turck …Y1… Magnetic Field Sensors Quick Start Guide - cover page
Brand
TURCK
Category
sensor
Document type
Quick Start Guide
Language
Chinese
Pages
4
File format
PDF
File size
277 KB
Published
03 November, 2023
Updated
03 November, 2023
MD5 checksum
0AF38EFFCCB1DB1F108F1364759349C3

About this manual

This quick start guide from Turck covers the …Y1… product series of magnetic field sensors. The sensors detect metallic objects without contact or wear, with a typical application being detection of the piston position in pneumatic cylinders. They have an output in accordance with EN 60947-5-6 (NAMUR), are compatible with all standard NAMUR processing units, and are intrinsically safe for operation in the Ex area.

The guide states the intended use and obvious misuse, gives general safety instructions and notes on explosion protection, and describes installing, connection, commissioning and operation. For safety-related applications it points to the separate safety manual, and it refers to the data sheet for wiring diagrams, pin assignment and detection range. It also covers the yellow status LED, repair handling and disposal. The document is printed in Chinese, German and English. This manual is written in Chinese.

What's inside

  • Other documents
  • Intended use
  • Obvious misuse
  • General safety instructions
  • Notes on explosion protection
  • Installing
  • Connection
  • Commissioning
  • Operation – LEDs
  • Repair

Specifications

OutputIn accordance with EN 60947-5-6 (NAMUR)
Protection typeIntrinsically safe, suitable for operation in the Ex area
Switch-on delay80 ms
Status LEDYellow: off = no magnetic field detected, output not switched; on = magnetic field detected, output switched
EMCMeets EMC requirements for industrial areas

Frequently asked questions

What is the …Y1… magnetic field sensor used for?

It detects metallic objects without contact and without wear; a typical application is detecting the piston position in pneumatic cylinders.

How long does the sensor take to become operational after power-on?

Once the cables are connected and the supply voltage is switched on, the device becomes operational automatically after a switch-on delay of 80 ms.

What does the yellow LED indicate?

When the yellow LED is on, a magnetic field is detected and the output is switched; when it is off, no magnetic field is detected and the output is not switched.

Can the device be repaired?

No, the device is not intended for repair. Defective devices should be taken out of operation and sent to Turck for fault analysis.

Download PDF (277 KB)

More TURCK Manuals


View all TURCK manuals →