Brand
TURCK
Category
sensor
Document type
Product Leaflet
Language
English
Pages
4
File format
PDF
File size
394 KB
Published
11 November, 2026
Updated
11 November, 2026
MD5 checksum
12B07936DA746A4FC8A17FA7DEEBE63D

About this manual

This document is a technical datasheet for the Turck BI10-P30-Y1X/S97 inductive sensor, designed for use in explosion hazardous areas. The sensor features a threaded barrel with an M30 x 1.5 connection and a rated switching distance of 10 mm.

Key specifications include a 2-wire NAMUR output function, a nominal voltage of 8.2 VDC, and an ambient temperature range of -40 to +70 °C. The device is approved for use in Ex ia IIC T6 Gb and Ex ia IIIC T115 °C Da zones.

What's inside

  • Functional principle
  • Technical data
  • Accessories
  • Intended use
  • Installation / Commissioning
  • Operating manual

Specifications

Rated switching distance10 mm
Mounting conditionsflush
Ambient temperature-40…+70 °C
Output function2-wire, NAMUR
Voltage8.2 VDC
Threaded barrelM30 x 1.5
Protection classIP67
Housing materialplastic, PA

Frequently asked questions

What is the rated switching distance?

The rated switching distance (Sn) is 10 mm.

Is the sensor suitable for explosion hazardous areas?

Yes, it is approved for use in Ex ia IIC T6 Gb and Ex ia IIIC T115 °C Da zones.

Can the sensor be repaired?

No, repairs are not possible as the approval expires if the device is repaired or modified.