Turck EZ-track LTX R10 magnetostrictive linear displacement transducer manual covering installation, wiring, settings, specifications and troubleshooting.
The Turck EZ-track LTX R10 is a magnetostrictive linear displacement transducer (LDT) for continuous machine positioning. It is completely absolute, uses a non-contact design, has auto-tuning capability, and has an analog output programmable over the active stroke length.
This manual covers unpacking, installation on mounting brackets or in hydraulic cylinders, wiring connections, features, zero and span setting, specifications, part numbering, and troubleshooting.
| Output options | 0-10VDC, 10-0VDC, 4-20mA, or 20-4mA |
|---|---|
| LED yellow indication | Magnet is out of the programmed active range but still within the active stroke area |
| LED red indication | Loss of magnet; voltage output goes to 0 volts and current output goes to 3.8mA |
| Current output outside set span | 3.9mA or 20.1mA |
| Current output in Null or Dead Zones or on magnet loss | 3.8mA |
| Voltage output outside programmed range | 0 volts below programmed zero point and 10 volts above programmed span |
| Ferromagnetic material clearance | No closer than 0.25 inch from rod end or magnet |
| Support bracket rod length | Recommended for rods 30-71 inches; additional brackets for rods 72 inches or longer |
| Support bracket spacing | Increments of 48 inches |
| Split magnet clearance | Not more than 0.2 inch from rod |
| Hydraulic cylinder magnet clearance | Magnet should not be closer than 2.0 inches from base of hex head when fully retracted |
| Hydraulic cylinder magnet options | Standard 1.29-inch four-hole magnet (P/N STM-AL-R10) or 1.0-inch countersunk magnet (P/N CM-R10) |
A red LED indicates loss of magnet; voltage units output 0 volts and current units output 3.8mA.
Yes, all units can be changed from 0-10VDC to 10-0VDC or from 4-20mA to 20-4mA.
The standard magnet is 1.29 inches in diameter, and a 1.0-inch magnet is available for countersunk mounting.
The magnet is out of the programmed active range but still within the active stroke area.