Turck EZ-track LTX R10 Series Analog Manual

Turck EZ-track LTX R10 magnetostrictive linear displacement transducer manual covering installation, wiring, settings, specifications and troubleshooting.


Turck EZ-track LTX R10 Series Analog Manual - cover page
Brand
TURCK
Category
sensor
Document type
User Manual
Language
English
Pages
20
File format
PDF
File size
842 KB
Published
17 November, 2026
Updated
17 November, 2026
MD5 checksum
5BB0DC02008DE17D6AEBA1269227A043

About this manual

The Turck EZ-track LTX R10 is a magnetostrictive linear displacement transducer (LDT) for continuous machine positioning. It is completely absolute, uses a non-contact design, has auto-tuning capability, and has an analog output programmable over the active stroke length.

This manual covers unpacking, installation on mounting brackets or in hydraulic cylinders, wiring connections, features, zero and span setting, specifications, part numbering, and troubleshooting.

What's inside

  • Chapter 1: LTX R10 Analog Overview
  • Chapter 2: Installing
  • 2.1 Installing to a Mounting Bracket
  • 2.2 Installing in a Hydraulic Cylinder
  • Chapter 3: Wiring
  • 3.2 Features
  • 3.3 Setting Zero & Span Position
  • 3.4 Specifications
  • Appendix A: Troubleshooting

Specifications

Output options0-10VDC, 10-0VDC, 4-20mA, or 20-4mA
LED yellow indicationMagnet is out of the programmed active range but still within the active stroke area
LED red indicationLoss of magnet; voltage output goes to 0 volts and current output goes to 3.8mA
Current output outside set span3.9mA or 20.1mA
Current output in Null or Dead Zones or on magnet loss3.8mA
Voltage output outside programmed range0 volts below programmed zero point and 10 volts above programmed span
Ferromagnetic material clearanceNo closer than 0.25 inch from rod end or magnet
Support bracket rod lengthRecommended for rods 30-71 inches; additional brackets for rods 72 inches or longer
Support bracket spacingIncrements of 48 inches
Split magnet clearanceNot more than 0.2 inch from rod
Hydraulic cylinder magnet clearanceMagnet should not be closer than 2.0 inches from base of hex head when fully retracted
Hydraulic cylinder magnet optionsStandard 1.29-inch four-hole magnet (P/N STM-AL-R10) or 1.0-inch countersunk magnet (P/N CM-R10)

Frequently asked questions

What does a red diagnostic LED indicate?

A red LED indicates loss of magnet; voltage units output 0 volts and current units output 3.8mA.

Can the analog output direction be reversed in the field?

Yes, all units can be changed from 0-10VDC to 10-0VDC or from 4-20mA to 20-4mA.

What magnet sizes are available for hydraulic cylinder installation?

The standard magnet is 1.29 inches in diameter, and a 1.0-inch magnet is available for countersunk mounting.

What does a yellow diagnostic LED indicate?

The magnet is out of the programmed active range but still within the active stroke area.

Download PDF (842 KB)

More TURCK Manuals


View all TURCK manuals →