Product manual for the Parker 514C DC controller covering installation, commissioning, diagnostics, technical specifications and safety information.
This product manual covers the Parker 514C DC controller, a single-phase DC motor speed controller designed for industrial environments. It controls the speed of DC shunt wound or permanent magnet motors in all 4 quadrants of operation, operating from a 110 V ac to 415 Vac, 50 or 60 Hz supply. Speed is controlled via a closed loop system using tachogenerator or armature voltage feedback, with a current loop and stall detection for motor protection.
The manual is organized into chapters covering product overview and technical specification, pre-installation planning with wiring diagrams and terminal descriptions, installation procedure, setting-up and commissioning, diagnostics and fault finding, certification, and service and repair. It also includes a terminal comparison for users upgrading from the 540/1 series, which the 514C is designed to be functionally equivalent to.
| Product range ratings | 4A, 8A, 16A, 32A DC full load current |
|---|---|
| Supply voltage | 110 V ac to 415 Vac at 50 or 60 Hz, single phase |
| Speed control | Closed loop with proportional integral control; feedback from armature voltage or tachogenerator |
| 100% load regulation | 2% typical (armature voltage), 0.1% typical (tachogenerator) |
| Maximum torque/speed range | 20:1 (armature voltage), 100:1 (tachogenerator) |
| Speed overload | 150% for 60 seconds |
| Torque control accuracy | 2% |
| Analogue setpoint input | 0 to ±10V, 100 Kohm |
| Tachogenerator input | 0 to ±350Vdc, 220 Kohm |
| Thermistor / microtherm input | <200 ohm = normal, >1800 ohm = overtemperature |
| Digital inputs | Run, Enable, Stall Override: +10 to +24V, 100 Kohm |
| Digital outputs | Health, Zero Speed or Setpoint: +24V, 50 mA source |
| Motor protection | Stall detection removes current after approximately 60 seconds; instantaneous overcurrent trip on short circuit |
Allow at least 5 minutes for the drive's capacitors to discharge to safe voltage levels (<50V), and confirm with a meter capable of measuring up to 1000V dc & ac rms.
Use only a meter to IEC 61010 (CAT III or higher), always starting with the highest range; CAT I and CAT II meters must not be used.
The 514C is designed to be functionally equivalent to the 540 series controllers, not a direct replacement; the manual includes a terminal-to-terminal comparison of 540/1 to 514C.
It is designed to control the speed of DC shunt wound or permanent magnet motors in all 4 quadrants of operation.