This document is the user manual of N2 Compact nitrogen generator. It introduces the safety information, installation, operation and maintenance of the device.
This user guide provides comprehensive instructions for the Parker NITROSource Compact Nitrogen Gas Generator models N2C-2, N2C-4, N2C-6, and N2C-8. It covers essential topics including safety information, mechanical and electrical installation, unpacking, and system layout recommendations. The guide details the operation of the generator, including starting and stopping procedures, menu interface usage, and parameter settings such as oxygen content and economy mode.
| Flow Rate | 47.64 m3/hr |
|---|---|
| Compliance Standard | EN 61010-1: 2010 |
| Compliance Standard | EN 61000-6-2: 2005 |
| Compliance Standard | EN 61000-6-4: 2007 |
Ensure adequate ventilation as breathing 100% nitrogen will produce immediate unconsciousness and death due to lack of oxygen.
Only competent personnel trained, qualified, and approved by Parker should perform installation, commissioning, service and repair procedures.
Interference with the calibration warning labels will invalidate the gas generator's warranty and may incur costs for re-calibration.