OIL-X Air Compressor Filter Oil User Manual, introduces the features and characteristics of the oil filter, installation instructions, maintenance and maintenance
This document is the user manual for the Parker OIL-X series of compressed air filters. It provides instructions for the installation of the system, including specific recommendations for models 050 and 055, and general guidelines for installing purification equipment to protect downstream applications. The manual details the startup procedure, emphasizing the need to pressurize the filter gradually to prevent damage. This manual is written in Italian.
| Replacement Interval for Coalescence and Dry Anti-Particulate Elements | every 12 months (8736 hours) |
|---|---|
| Nominal Inlet Temperature for OIL-X Grade ACS | 21 °C |
| Maximum Inlet Oil Vapor Concentration for OIL-X Grade ACS | 0.018 mg/m3 |
| Duration of OIL-X Grade ACS Element at Nominal Conditions | 650 hours |
They must be replaced every 12 months (8736 hours) together with the automatic float drain.
The filter offers optimal performance at a nominal inlet temperature of 21 °C.
Open the inlet valve slowly to pressurize the filter gradually and wait 1 minute before opening the outlet valve.