KEYENCE XM-WA WLAN module instruction manual covering safety symbols, CE/UKCA and CSA compliance, FCC/ISED regulations, and warranty terms.
The KEYENCE XM-WA WLAN module instruction manual explains the safety symbols used in the document and provides regulatory and certification information. It covers CE and UKCA markings, the RE Directive, CSA certification, FCC regulations, and ISED regulations.
The manual lists operating conditions and radio specifications, including a 2402 to 2480 MHz frequency band, 8 dBm maximum radio-frequency power, indoor use only, and use at altitudes of 2000 m or less. It also states that the equipment can be used with XM 5000 only and includes KEYENCE warranty and disclaimer terms.
| Frequency band of operation | 2402 to 2480 MHz |
|---|---|
| Maximum radio-frequency power | 8 dBm |
| Overvoltage category | I |
| Pollution degree | 2 |
| Altitude | 2000 m or less |
| Operating environment | Indoor use only |
| Applicable standards | (BS)EN61010-1, EN301 489-1, EN301 489-17, EN300 328 |
| Separation distance | At least 20 cm |
The manual states an operating frequency band of 2402 to 2480 MHz.
The maximum radio-frequency power is 8 dBm.
The manual states that the equipment can be used with XM 5000 only, and it describes use of XM-C5000 with XM-WA.
At least 20 cm separation distance must be maintained from the radiator to all persons.