Freescale HVP-MC3PH high-voltage motor control platform user guide for the 115/230 V, 1000 W three-phase development board.
Freescale's three-phase high-voltage motor control platform (HVP) is a 115/230 volt, 1000 watt power stage supplied in the HVP-MC3PH kit. With a controller card, it provides a ready-made software development platform for more than one-horsepower off-line motors and supports three-phase AC induction, BLDC, or PMSM motor control algorithms. The HV AC power stage includes an active interleaved power factor correction circuit for PFC algorithm development.
The guide covers main board introduction, setup, design details, useful tips, and controller cards. It also includes safety warnings for high-voltage operation, including the requirement that the main board cannot operate without a controller card.
| Input voltage | AC: 90-240V / DC: 110-390VDC |
|---|---|
| Output power | up to 1kW |
| Power factor correction | On-board interleaved PFC |
| Optical isolation | 5KV |
| Fault protection | Hardware over-current, overvoltage faults |
| Motor sensor interface | Encoder, Hall, Tacho generator |
| Analog sensing | Input voltage, DC bus voltage, DC bus current, phase currents, back-EMF voltage, PFC currents, IGBT module temperature |
| Controller card interface | PCI Express 64 |
| EMI filter | Included |
| Test points | Included |
| Certification | CE/FCC certified |
| DC input voltage (electrical characteristics) | 110 / 310 / 390 V |
| AC input voltage (electrical characteristics) | 90 / 220 / 240 V |
| Quiescent current | 9 mA |
| Analog output range | 0 to 3.3 V |
| Phase current measurement sensitivity | 206.25 mV/A |
| PFC current measurement sensitivity | 412.5 mV/A |
| Voltage measurement sensitivity | 7.62 mV/V |
| Peak output current | 8 A |
| Brake resistor output maximal current | 8 A |
| Maximal DC bus voltage | 410 V |
| Total power dissipation | 85 W |
| DC input voltage (absolute maximal ratings) | 135 to 430 V |
| Peak phase output current (absolute maximal ratings) | 15 A |
No. The main board is not able to operate without a controller card.
A DC supply is strongly recommended unless power factor correction is being investigated, and the supply should be current limited to fewer than 4 amps during debugging.
Two: a USB line through galvanic isolation and a non-isolated line terminated at connector J2.
Three-phase AC induction, BLDC, or PMSM motors.