Operating instructions manual for the FLAGRO FVO-200RC42 indirect fired space heater, covering installation, startup, maintenance, and safety precautions…
This document serves as the operating instructions manual for the FLAGRO FVO-200RC42 indirect fired space heater, certified for use in Canada and the U.S.A. It provides comprehensive guidance on installation requirements, including clearance distances and venting specifications, as well as electrical and fuel connections. The manual outlines specific safety warnings regarding fire, explosion, and carbon monoxide hazards, emphasizing that the unit is intended primarily for temporary heating of buildings under construction or repair.
| Input | 185,000 Btu |
|---|---|
| Fuel | No.1, No. 2, diesel or kerosene |
| Fuel Pressure | 180 psi |
| Nozzle | 1.10 x 70A |
| Electrical | 115V 15 AMP |
| Ignition | Direct Spark Ignition |
| Air Circulation | 2600 cfm |
| Fuel Consumption | 1.30 Gal/hr |
The heater will operate with No.1, No.2, Diesel or Kerosene.
The heater requires a 115V supply and 15 amps for proper operation.
There must be 2-4 gallons of fuel in the tank for the heater to start properly.
The fuel filter insert should be changed once per month.