This instruction manual contains the operating instructions for the THC-355CDF(Dual Fuel) Industrial/Commercial Directional Space Heater. It includes information on how to use, maintain and care for the heater.
The THC-355CDF is a dual fuel industrial/commercial directional space heater that operates on propane and natural gas. The manual states it is suitable for indoor or outdoor installation, is an unvented and unattended type, and is certified to ANSI std Z83.7 2000 and CGA 2.14 M2000.
The operating instructions cover safety warnings, installation and fuel supply connections, electrical grounding and power supply indicator, clearance to combustibles, ducting, maintenance, start-up and shutdown, heater specifications, and troubleshooting analysis.
| Model | THC-355CDF |
|---|---|
| Fuel type | Dual fuel: propane and natural gas |
| Maximum input | 330,000 btuh for propane and 330,000 btuh for natural gas |
| Propane inlet pressure | Min. 11" WC / Max. 14" WC |
| Natural gas inlet pressure | Min. 9.0" WC / Max. 14" WC |
| Burner manifold pressure | 7.75" WC propane; 5.5" WC natural gas |
| Fuel consumption per hr | 16.0 lbs propane; 307 CFH natural gas |
| Temperature rise above ambient | 160°F propane; 150°F natural gas |
| Amp draw | 21 amps starting; 7 amps continuous |
| Outlet size | 12.5" x 10.75", designed for 18" dia. ducting |
| Dimensions | 42" x 46" x 32.5" H x L x W (in.) |
| Shipping weight | 390 lbs |
| Air circulation | 2400 CFM |
| Approval | cETLus listed |
It operates on propane and natural gas only.
The listed clearances are top 5 ft, front 2 ft, sides 1 ft, and rear 2 ft.
Use only manufacturer ducting, with a maximum of 12 ft of ducting.
Call your supplier for service.