This is an operating manual for a gas-fired space heater, including precautions before use, operating methods, etc.
The Flagro FVNP-400 is an indirect fired space heater certified for indoor and outdoor use in Canada and the U.S.A. to ANSI Z83.7/CSA 21.4 2000. It is intended primarily for temporary heating of buildings under construction, alteration, repair or emergencies and operates on propane or natural gas, not both.
The operating instructions cover installation, cylinder connection, piping and pressures, fuel and hoses, electrical supply and indicator lights, clearances, ducting, flue pipe and venting, maintenance, startup and shutdown. Specifications include 390,000 btuh input, 2500 cfm air circulation and direct spark ignition; a parts list for the FVNP-400 is also included.
| Input | 390,000 btuh |
|---|---|
| Fuel | Propane / Natural Gas |
| Manifold Pressure | 1.5” W.C. Propane; 2.0” W.C. NG |
| Maximum Inlet Pressure | 13.0” W.C. Propane; 10.0” W.C. NG |
| Ignition | Direct Spark Ignition |
| Air Circulation | 2500 cfm |
| Fuel Consumption | 18.5 lbs/hr Propane; 380 cfh NG |
| Approval | cETLus listed |
It operates on propane or natural gas, but not both.
The input rating is 390,000 btuh.
It requires 15 amps for proper operation.
Service and maintenance should only be done by a qualified service person.