FVO-400RC is certified for use in Canada and the USA as an indirect fired space heater for construction, alterations, repairs or emergencies.
The FLAGRO FVO-400RC is an indirect fired space heater certified for use in Canada and the U.S.A. under CSA B140.8 / CSA B140.02003 and UL 733. The manual includes general hazard warnings and states the heater is intended primarily for temporary heating of buildings under construction, alteration, repair or emergencies.
It covers specifications, installation, electrical and flue requirements, ducting, maintenance, start-up and shutdown, troubleshooting if the heater fails to start, safe operation precautions, and combustion air adjustments. Listed specifications include a 325,000–390,000 input range, No.1/No.2/diesel/kerosene fuel, 170 psi fuel pressure, 4000 cfm air circulation and 2.75 Gal/hr fuel consumption.
| Model | FVO-400RC |
|---|---|
| Input | 325,000 – 390,000 |
| Fuel | No.1, No. 2, diesel or kerosene |
| Nozzle | 2.25 x 45B 390,000 Btu; 2.00 x 60B/W 353,000 BTU; 1.75 x 60B/W 325,000 BTU |
| Electrical requirement | 15 amps |
| Ducting options | 2 x 12 in or 1 x 16 in |
| Inlet ducting diameter | 16 in |
The heater operates with No.1, No.2, diesel or kerosene.
It requires a grounded 115V 15-amp outlet for operation.
The fuel filter insert (Part# FVO-419) should be changed once per month.
Drain oil from the heat exchanger for 15–20 minutes before attempting to relight.