This is an instruction manual that mainly describes the operation method and precautions of the FVO-400 indirect fired space heater.
Flagro Industries Limited provides these operating instructions for the FVO-400 indirect fired space heater, a construction heater certified for use in Canada and the U.S.A. under CSA B140.8 and CSA B140.02003. The manual covers safety warnings, specifications, installation, clearances to combustibles, electrical supply and flue pipe requirements.
It also describes venting requirements, ducting, maintenance, start-up and shutdown procedures, troubleshooting if the heater fails to start, safe operation precautions, combustion air adjustments, the burner set-up chart and temperature feeler gauge adjustment.
| Input | 390,000 btuh |
|---|---|
| Fuel | No.1, No. 2, diesel or kerosene |
| Fuel Pressure | 150 psi |
| Nozzle | 2.25 x 45B (Delavan) |
| Ignition | Direct Spark |
| Air Circulation | 2500 cfm |
| Fuel Consumption | 2.75 Gal/hr |
| Approved | cETLus listed |
The FVO-400 has an input of 390,000 btuh.
It will operate with No.1, No.2, Diesel or Kerosene.
1 square inch of fresh air must be supplied for every 1000 btuh of heat.
The manual lists a 2.25 x 45B (Delavan) nozzle.