Digi-Star D3708-GB Analog Output 4-20mA User Manual

User and installer guide for the Digi-Star D3708-GB Analog Output module, covering technical specifications, safety, and parameter setup.


Digi-Star D3708-GB Analog Output 4-20mA User Manual - cover page
Brand
DIGI-STAR
Category
Industrial Supply
Document type
User Manual
Language
English
Pages
8
File format
PDF
File size
138 KB
Published
14 November, 2026
Updated
14 November, 2026
MD5 checksum
27C6A2F2AACDD18141C7EEE00F8CD087

About this manual

This manual provides instructions for the Digi-Star D3708-GB Analog Output module, which provides a 4-20mA (optional 0-5V) signal proportional to scale weight. It is compatible with EZIII series indicators (EZ2400, EZ3400, EZ3600) running software version EZ2 7.0 or higher.

The document details technical specifications such as operating temperature and output load resistance. It also explains how to connect the signal via J904 or J905 and guides users through setting parameters like ZEROUT, LOW WT, HIGHWT, and ANAOut to configure the output signal.

What's inside

  • Technical Specifications
  • Safety During Use
  • Introduction
  • Connections
  • Indicator Setup
  • Parameters
  • Zero Balance
  • Parameter Setup
  • Set up EZ2400
  • Set up EZ3400 / EZ3600

Specifications

Operating Temperature-30 to +40°C
Output Signal4-20mA (optional 0-5V)
Output Load Resistance< 350 Ω
Resolution16 bits
Non Linearity< +/- 0.012%
Gain Plus Offset Error+/- 0.15% max
Update Rate10x per second
Temperature Drift50ppm/ °C

Frequently asked questions

What is the default output signal configuration?

The option is standard configured as 4-20mA with a 0mA signal in case of an error in the weighing indicator.

Which indicators are compatible with this module?

This module can be added to any EZIII series indicator, except the EZ400.

Which connectors are used for the signal output?

The signal is supplied through J904 or J905.

Download PDF (138 KB)

More DIGI-STAR Manuals