This is the technical manual for Digi-Star EZ III series products, covering product specifications, power, load units, input and output interfaces, setup and calibration, troubleshooting, etc.
This manual covers the EZ III series of scale indicators, detailing specifications, power requirements, load cell connections, remote display options, and serial communications. It includes wiring tables, calibration procedures, error code references, and print format examples to aid installation and operation.
The document also lists applicable product models, optional upgrade kits, and provides troubleshooting guidance for common issues such as weighing errors and communication problems. Users can reference the Direct Access Numbers (D.A.N.) for quick configuration changes.
| Accuracy | 0.1% (system accuracy based on load cells) |
|---|---|
| Temperature Range | -20 to +140 °F (-29 °C to +60 °C) |
| Enclosure Rating | IP65, IEC 529 |
| Supply Voltage | 10.5 V to 16.0 VDC (10.2 V to 16.0 V for EZ2500V) |
The EZ III indicator provides an accuracy of 0.1% with system accuracy based on the load cells used.
It operates from a supply voltage of 10.5 V to 16.0 VDC (10.2 V to 16.0 V for the EZ2500V version).
The default baud rate is either 1200 or 9600, depending on the COM IN setting.