This manual provides operation, installation, calibration, and troubleshooting instructions for the Digi-Star GT400 weighing indicator.
The Digi-Star GT400 is a portable weighing indicator designed for use with load cells in various environments. It features a 6-digit LCD display, auto temperature compensation, and supports multiple transducer configurations up to eight units. The device includes options for remote displays, data downloading via serial port, and customizable print formats.
| Size | 7.33" long x 5.25" high x 3.38" wide (186mm x 133mm x 85mm) |
|---|---|
| Weight | 2 lbs (.91 Kg) |
| Transducer Excitation | 8 volts D.C. Nominal |
| Power Requirements | 10.5 to 16.0 V.D.C. |
| Gross Range | 999,999 max.display |
| Display Resolution | .01 to 50 selectable |
| Environmental Enclosure | IP65, IEC 529 |
The device requires a DC voltage between 10.5 and 16.0 volts.
It is capable of driving up to eight transducers.
A low battery warning is enabled at this nominal voltage.
No, you should not use running water or high pressure cleaners to clean the indicator.