3M 100 Series Head Hood User Manual

User manual for the 3M 100 series head hoods, covering assembly, usage, maintenance, and safety specifications for respiratory protection.


3M 100 Series Head Hood User Manual - cover page
Brand
3M
Category
Other products
Document type
User Manual
Language
English
Pages
15
File format
PDF
File size
609 KB
Published
13 October, 2026
Updated
13 October, 2026
Model
100
MD5 checksum
96541AAD7937B737F8D3137DE742925F

About this manual

This document provides usage instructions for the 3M 100 series head hoods, which offer protection for the face, hair, and shoulders when used with approved air-supplied filtering devices. The manual details the system description, including how air flows from the waist-mounted filter through the breathing tube to the hood.

What's inside

  • System Description
  • Usage Restrictions
  • Preparation and Assembly
  • Usage Instructions
  • Removal
  • Cleaning and Disinfection
  • Maintenance
  • Storage and Transport
  • Respiratory Protection Ratings

Specifications

Calculated Protection Factor (NPF)50
Assigned Protection Factor (APF)20
Storage Temperature Range-20*C to +50C
Shelf Life5 years

Frequently asked questions

What is the maximum harmful substance concentration for HT-101, HT-103, HT-111, HT-115, HT-120, HT-121, or HT-125?

These models cannot be used in environments where the concentration of harmful substances reaches 20 times the national occupational health standard.

Can the head hood be used in an oxygen-deficient environment?

No, it cannot be used when the oxygen volume concentration is below 19.5%.

What cleaning agents are prohibited for the head hood?

Gasoline, chlorinated degreasing liquids (such as trichloroethylene), organic solvents, or abrasive cleaning agents are prohibited.