Enphase IQ 7/IQ 7+/IQ 7X/IQ 7A Microinverter Installation and Operation Manual
This is the Portuguese-language installation and operation manual (document 141-00044-02, dated 28 December 2021) for Enphase IQ 7, IQ 7+, IQ 7X and IQ 7A microinverters. It is intended for professional personnel responsible for installation and maintenance of the Enphase IQ System.
The manual covers safety information and product labels, how the IQ series microinverters work and are monitored, installation planning and compatibility, a ten-step microinverter installation procedure, active configuration and monitoring, LED fault indications and troubleshooting, replacement of a microinverter, planning and ordering of the Enphase Q Cable, and technical data with model-specific specifications and connection diagrams. This manual is written in Portuguese.
| Maximum AC branch circuit breaker or fuse rating | 20 A |
|---|---|
| Required Enphase cable | Enphase Q Cable |
| Required monitoring device | Envoy-S |
| Chassis temperature above ambient in normal operation | 20 °C |
| Chassis temperature in extreme conditions | 90 °C |
No. They require the Enphase Q Cable and are not compatible with previous Enphase wiring.
An Envoy-S is required to monitor the performance of the IQ Microinverters.
No. It contains no user-serviceable parts; contact Enphase customer support for an RMA and the replacement process.
It must be protected with a breaker or fuse rated at no more than 20 A.