SOYAL AR-727-CM HTTP Server Operation Manual

The SOYAL AR-727-CM HTTP Server is a multifunctional device that provides a WEB service interface, cross-platform service, parameter settings, fire alarm unlocking settings, and DI/DO direct query control functions.


SOYAL AR-727-CM HTTP Server Operation Manual - cover page
Brand
Soyal
Category
Communications equipment
Document type
User Manual
Language
Chinese
Pages
27
File format
PDF
File size
16 MB
Published
24 November, 2023
Updated
24 November, 2023
MD5 checksum
2F3B0171079CCE6AD4885D0A72CD237D

About this manual

This manual describes the SOYAL AR-727-CM HTTP server used with AR-727-CM, AR-727-CM-IO-0804M, and enterprise-series controllers. It explains web-based setup, network settings, RS485 port settings, IO direct control, TCP/IP converter functions, fire alarm linkage, Server/Client mode, Modbus TCP to RTU, and password changes.

It also provides interface screenshots, parameter ranges, default login information, and a short FAQ with RS485 cable and connection recommendations. This manual is written in Chinese.

What's inside

  • Main functions
  • Controller system architecture
  • Login to WEB setting page
  • Device status view
  • Network parameter settings
  • RS485 port settings
  • IO direct control
  • TCP/IP converter settings
  • Fire alarm linkage
  • Server/Client mode

Specifications

Supported controllersAR-727-CM, AR-727-CM-IO-0804M, and enterprise-series controllers
Default IP address192.168.1.127
Default HTTP port80
TCP/IO control port1601 (default)
Modbus port502
RS485 local port1621 (range 1024-65535)
Baud rate9600
ParityNone (default)
Stop bits1 (default)
UART to network delay time10 ms
Minimum transfer bytes1024 (range 16-1024)
Socket timeout120 s (range 0-600)
Selected node ID0 (disabled by default; range 1-254)
Maximum controllers per RS485 channel8
Total controllers with two channels16
RS485 cable distance1200 m theoretical; 300 m recommended for parallel wiring
Recommended RS485 cableAWG22 twisted-pair shielded cable
Default loginSuperAdm / 721568 (firmware 2020/01/21 and later); admin / admim (earlier firmware)

Frequently asked questions

How many card readers or controllers can one RS485 channel connect?

The manual recommends connecting up to 8 card readers or controllers per RS485 channel.

What is the maximum RS485 cable length?

RS485 can theoretically reach 1200 m; for parallel wiring over 300 m, the manual recommends an AR-485REP-V3 signal repeater.

What cable type is recommended for RS485?

The recommended cable is AWG22 twisted-pair shielded cable.

What are the default web login credentials?

For firmware dated 2020/01/21 or later, the default account is SuperAdm and the default password is 721568.