Omron F3SJ-E/B Series Safety Light Curtain User's Manual

The F3SJ-E/B Series Safety Light Curtain is a photoelectric protective device that detects objects entering its protected area. It can be used to protect operators from injury by machines, or to prevent damage to machines. The device complies with IEC 61496-1 and IEC 61496-2 standards.


Omron F3SJ-E/B Series Safety Light Curtain User's Manual - cover page
Brand
Omron
Category
sensor
Document type
User Manual
Language
English
Pages
138
File format
PDF
File size
22 MB
Published
11 November, 2023
Updated
11 November, 2023
MD5 checksum
1DC2D9A306ED743962D9D01689C46A3E

About this manual

The Omron F3SJ-E/B Series Safety Light Curtain is described as electro-sensitive protective equipment (ESPE). This User's Manual describes its use and states that the product must be handled by a Responsible Person who is familiar with the machine to be installed.

The document includes safety precautions, legislation and standards, warranty and liability information. It lists conformity with EC Directives and standards such as EN 61496-1 (Type 4 ESPE) and ISO 13849-1, and it warns that installation and configuration must be performed by a sufficiently trained and qualified person.

What's inside

  • Introduction
  • Legislation and Standards
  • Read and Understand This Document
  • Precautions on Safety
  • Meanings of Alert Symbols
  • Alert Statements in This Manual
  • Warranty
  • Limitations of Liability
  • Suitability for Use

Specifications

Safety categoryCategory 4, PL e
Safety integrity levelSIL3
ESPE typeType 4 ESPE
AOPD typeType 4 AOPD
Machinery Directive2006/42/EC
EMC Directive2004/108/EC

Frequently asked questions

What is the Omron F3SJ-E/B Series?

It is a Safety Light Curtain. The manual describes it as electro-sensitive protective equipment (ESPE) in accordance with EU Machinery Directive Index Annex V, Item 2.

Can the F3SJ-E/B be used as a safety system for pressing or shearing machines in Japan?

No. The text states that the F3SJ-E/B does not receive type approval under Article 44-2 of the Industrial Safety and Health Act of Japan and cannot be used as the prescribed safety system for pressing or shearing machines.

Who must install, configure, and incorporate the F3SJ-E/B into a machine control system?

It must be installed, configured, and incorporated by a sufficiently trained and qualified person.

What safety integrity level is stated for the F3SJ-E/B?

The document states SIL3.