The DW01E is a专用芯片 designed for single-cell lithium-ion battery-powered systems (such as mobile phone battery packs) to prevent lithium-ion batteries from being damaged or having their service life reduced due to overcharging, over-discharging and/or overcurrent.
This Chinese user manual describes the DW01E, a dedicated IC for single-cell lithium-ion battery powered systems such as cell phone battery packs. It is used to prevent the battery from being damaged or having its life shortened by overcharge, overdischarge and/or overcurrent, and its small package and low external component count allow it to fit into limited battery pack space.
The document introduces the product features and pinout, then explains each protection function in detail: normal operation, overcharge protection, overdischarge protection and sleep state, overcurrent protection, load detection after overcharge, charger detection after overdischarge, and the selectable 0V battery charging function. It also gives timing diagrams, absolute maximum and DC characteristic tables, a typical single-cell protection circuit with external component values, and SOT-23-6 package dimensions. This manual is written in Chinese.
| Overcharge detection voltage | 4.40 V, ±50 mV |
|---|---|
| Overcharge release voltage | 4.10 V, ±50 mV |
| Overdischarge detection voltage | 2.80 V, ±100 mV |
| Overdischarge release voltage | 3.00 V, ±100 mV |
| Discharge overcurrent detection voltage | 175 mV, ±35 mV |
| Load short-circuit detection voltage | 0.80 V, ±300 mV |
| Overcharge detection delay time | 70 ms typical |
| Operating mode supply current | 3.0 uA typical, 6.0 uA maximum at VCC=3.9V |
| Sleep mode current | 0.1 uA typical at VCC=2.0V |
| Operating temperature range | -40 °C to +85 °C |
| Package | SOT23-6 |
It is a dedicated IC for single-cell lithium-ion battery powered systems such as cell phone battery packs, used to prevent damage or reduced battery life from overcharge, overdischarge and/or overcurrent.
The DW01E is supplied in a SOT-23-6 package.
It is calculated as RON = VOIX/(2*IT), where IT is the overcurrent threshold current; for a 3 A threshold the on-resistance must be 25 mΩ.
The device operates over -40 °C to +85 °C.