Kutai ADVR-053 Automatic Voltage Regulator User Manual

ADVR-053 Automatic Voltage Regulator Manual for self-excited brushless generators, universal 5 Amp AVR for 170 - 520 Vac.


Kutai ADVR-053 Automatic Voltage Regulator User Manual - cover page
Brand
KUTAI
Category
Power Management
Document type
User Manual
Language
Chinese
Pages
6
File format
PDF
File size
665 KB
Published
10 November, 2023
Updated
10 November, 2023
MD5 checksum
ACBA6D176575EECD2BA7FD407DF56916

About this manual

The ADVR-053 is described as an advanced version of the EA05A automatic voltage regulator for self-excited brushless generators, with a wide voltage regulation range, simple installation, fast response, and added over-excitation protection. It uses a CPU core to reduce temperature drift of analog components and includes low-frequency U/F and over-excitation O/E indicator lamps.

The manual covers technical parameters, wiring, DIP switch settings, protection systems, adjustment, generator startup adjustment, residual magnetism voltage induction, troubleshooting, and diagrams with dimensions. This manual is written in Chinese.

What's inside

  • Overview
  • Technical Parameters
  • Wiring
  • DIP Switch Settings
  • Protection System
  • Adjustment
  • Generator Startup Adjustment
  • Residual Magnetism Voltage Induction
  • Troubleshooting Table
  • Diagrams and Dimensions

Specifications

Field output voltageContinuous 63 Vdc at 220 Vac power input
Field output currentContinuous 5 A; 7 A for 10 seconds
Field impedance15 ohms minimum, 100 ohms maximum
Over-excitation protection voltage78 Vdc +/- 5% at 220 Vac power input
Fuse5 x 20 mm S505-5A / 250 V slow-blow
Operating temperature-40 to +70 C
Storage temperature-40 to +85 C
Residual voltage for build-upAbove 5 Vac
Dimensions107.0 (L) x 75.0 (W) x 48.5 (H) mm

Frequently asked questions

How can voltage be rebuilt after an over-excitation shutdown?

Stop generator operation for about 10 seconds, then restart it to rebuild voltage.

What residual voltage is needed for voltage build-up?

The power input residual voltage must be above 5 Vac.

What should be checked if the generator does not generate voltage after correct installation?

Possible causes include reversed residual magnetism polarity or low residual voltage; solutions include reversing F+ and F- or rebuilding residual magnetism.

Download PDF (665 KB)

More KUTAI Manuals