The document is about the user manual of an air conditioner.
This is the owner's manual for the Toshiba split-type air conditioner, covering indoor unit RAS-22, 24J2KCV(HK) and outdoor unit RAS-22, 24J2ACV(HK) for general public use. It is printed in English and Traditional Chinese and opens with danger, warning and caution notices on installation, electrical safety, refrigerant use and general handling of the unit.
The manual then explains the indoor unit display and preparation before use (filters, remote batteries, clock setup), followed by remote control operation: automatic, cooling/fan only, dry, Hi-POWER and ECO modes, airflow direction, on/off and daily timers, display lamp brightness, temporary and preset operation, auto restart setting, comfort sleep and self-cleaning. A maintenance section covers filter cleaning every 2 weeks, and operating condition ranges for cooling and dry modes are listed.
| Temperature setting range | Min. 17°C, Max. 30°C |
|---|---|
| Cooling operation conditions (outdoor / room) | -10°C ~ 46°C / 21°C ~ 32°C |
| Dry operation conditions (outdoor / room) | -10°C ~ 46°C / 17°C ~ 32°C |
| Remote control batteries | 2 × AAA |
Press and hold the [OPERATION] button on the indoor unit for 3 seconds; 3 beeps sound, and the OPERATION lamp blinks when turning it on and does not blink when turning it off.
Clean them every 2 weeks: open the air inlet grille, remove the filters, vacuum or wash and dry them, then reinstall.
Yes. Pressing the RESET button starts or stops the unit in automatic operation with a preset temperature of 24°C and automatic fan speed.
Stop the air conditioner and disconnect the power supply or turn off the breaker.