Panasonic FX-551 Series Digital Fiber Sensor Amplifier Instruction Manual

This PDF document is an instruction manual for the Panasonic FX-551 series digital fiber sensor amplifier. It includes an overview of the product, function introductions, usage methods and precautions.


Panasonic FX-551 Series Digital Fiber Sensor Amplifier Instruction Manual - cover page
Brand
Panasonic
Category
sensor
Document type
User Manual
Language
English
Pages
4
File format
PDF
File size
1.1 MB
Published
03 November, 2023
Updated
03 November, 2023
MD5 checksum
B0937954FB26F73E99EB73364F9F752C

About this manual

This instruction manual from Panasonic describes the FX-551 Series digital fiber sensor amplifier. It opens with a safety warning that the product must never be used as a sensing device for personnel protection, and states that the product complies with the EMC Directive for CE marking. Part names and key functions of the amplifier are also listed, including the UP, DOWN and SET keys, the MODE key, the digital display and the mode indicators.

The manual then explains mounting on a 35 mm width DIN rail, connecting fiber cables with the fiber lock lever, and cascading amplifiers with quick-connection cables and MS-DIN-E end plates. I/O circuit diagrams show NPN and PNP output types and the FX5510 terminal arrangement, and the remaining sections cover the operation procedure, teaching mode, threshold value fine adjustment, key lock, sensing output operation mode, light sensitivity setting mode and PRO mode.

What's inside

  • Part description
  • Mounting
  • How to connect the fiber cable
  • How to cascade
  • I/O circuit diagrams
  • Operation procedure
  • Teaching mode
  • Threshold value fine adjustment function
  • Key lock function
  • Sensing output operation mode

Specifications

Additional amplifiers in series connectionUp to 15 series connection types via sub cables (optional)
Interference preventionUp to four units by setting different frequencies
Mounting rail35 mm width DIN rail
Output typesNPN output type and PNP output type
Terminal arrangementFX5510: 1 +V, 2 Sensing output, 3 0V
Applicable EU directiveEMC Directive

Frequently asked questions

Can the FX-551 Series amplifier be used for personnel protection?

No. The manual states it must never be used as a sensing device for personnel protection; products meeting laws and standards such as OSHA, ANSI or IEC should be used for that purpose.

How many amplifiers can be added to one main connection cable?

Up to 15 series connection types can be added using sub cables (optional), and they must be mounted on a DIN rail when connected in cascade.

How can interference between units be prevented?

The product has no automatic interference prevention function, but interference can be prevented for up to four units by setting different frequencies.

Download PDF (1.1 MB)