This manual provides detailed information on the features and usage of the 2875 0697ASB type “SSJ” series vertical jet pump.
This owner's manual covers the STA-RITE "SSJ" Series vertical jet pump, model 2875 0697ASB, published by Pentair Ltd. in 2013. It is an installation/operation/parts manual that begins with safety instructions and the limited warranty, then explains how to match the pump to the ejector and well depth.
The installation section describes deep well piping for single pipe (2" wells) and double pipe (4" and larger wells) setups, plastic and steel pipe installation, ejector placement, and well casing adapters. Later sections cover electrical wiring, operation, maintenance, repair parts and troubleshooting. Assistance is available by phone at 1-888-782-7483 or through sta-rite.com.
| Well depth range | 25 ft. to 130 ft. |
|---|---|
| Relief valve requirement (booster use) | Full pump flow at 75 psi |
| Drive pipe size (double pipe) | 1" |
| Suction pipe size (double pipe) | 1-1/4" |
| Ejector setting depth | 10 to 20 feet below lowest water level, at least 5 feet above well bottom |
The pump is designed for wells from 25 ft. to 130 ft. depth from well head to water, and must be matched to the ejector and well depth for proper performance.
Water Systems Products including jet pumps are warranted for 12 months from date of original installation, or 18 months from date of manufacture, whichever occurs first.
No. Do not allow the pump or any system component to freeze, as this will void the warranty, and the pump should only pump water.
Release all pressure on the system and disconnect power before working on the pump, motor or tank, and ground the motor before connecting it to the power supply.