Sta-Rite Max-E-Glas II and Dura-Glas II Centrifugal Pumps with Integral Trap Owner's Manual

This manual is for Sta-Rite P4R and P4E Series II self-priming centrifugal pump, it introduces the features and characteristics of the pump, installation, operation and maintenance information


Sta-Rite Max-E-Glas II and Dura-Glas II Centrifugal Pumps with Integral Trap Owner's Manual - cover page
Brand
STA-RITE
Document type
User Manual
Language
English
Pages
20
File format
PDF
File size
288 KB
Published
12 July, 2012
Updated
30 September, 2023
Models
P4E, P4EA, P4R, P4RA
MD5 checksum
5E9A4285872999C00C2E53A4D5A4F556

About this manual

This owner's manual covers the installation, operation, storage, winterizing, servicing, troubleshooting, and repair parts for Sta-Rite Max-E-Glas II and Dura-Glas II Series II self-priming centrifugal pumps. The document applies to models in the P4E, P4EA, P4R, and P4RA series.

What's inside

  • Safety Instructions
  • Installation
  • Operation
  • Storage/Winterizing
  • Pump Service
  • Troubleshooting Guide
  • Repair Parts List

Frequently asked questions

What is the maximum water pressure allowed for testing the pump system?

The water pressure for the test must be less than 25 PSI.

What is the maximum water temperature allowed for testing the pump system?

The water temperature for the test must be less than 100° F.

How long should the pressure test be limited to?

The test must be limited to 24 hours.

Download PDF (288 KB)

More STA-RITE Manuals


View all STA-RITE manuals →