Pelco D Protocol Engineering Design Standard TF-0002 Manual

This manual provides a detailed description of the Pelco D protocol's standard command set, extended command set, and advanced feature set. It also provides example messages and responses.


Pelco D Protocol Engineering Design Standard TF-0002 Manual - cover page
Brand
Pelco
Category
Other Electronics
Document type
Programming Manual
Language
English
Pages
20
File format
PDF
File size
243 KB
Published
03 November, 2023
Updated
03 November, 2023
MD5 checksum
7A73A768120780BE5C3038442A0D9B2B

About this manual

This Pelco Engineering Design Standard, numbered TF-0002 and issued as Version 2, Revision 1 on August 15, 2003, is the Pelco “D” Protocol Manual. It describes the minimum requirements for implementing the Pelco “D” protocol, which is used to communicate between a controlling device (for example a matrix switching system) and a receiver/driver (for example a dome drive).

The manual explains the byte format, the message format with its sync byte, address, two command bytes, two data bytes and checksum, the standard command set, extended commands, the advanced feature set, creating labels, example messages, responses and opcode descriptions. Appendix A lists advanced feature commands and Appendix B details document changes.

What's inside

  • The Byte Format
  • The Message Format
  • The Standard Command Set
  • Extended Commands
  • Advanced Feature Set
  • Creating Labels
  • Example Messages
  • Responses
  • Opcode Descriptions
  • Appendix A: Advanced Feature Commands

Specifications

Character format1 start bit, 8 data bits, 1 stop bit, no parity
Sync byte0xFF
Message fieldsSync byte, address, command 1, command 2, data 1, data 2, checksum
Checksum8 bit (modulo 256) sum of payload bytes 2 through 6
Pan speed range0x00 to 0x3F, plus 0x40 for turbo speed
Tilt speed range0x00 to 0x3F; turbo speed not allowed
Query response part number field15 bytes

Frequently asked questions

What is the sync byte value in the Pelco D protocol?

The synchronization byte is always 0xFF.

How is the message checksum calculated?

It is the 8 bit (modulo 256) sum of the payload bytes, bytes 2 through 6 of the message.

What byte format do transmitters and receivers use?

A single character is sent as 1 start bit, 8 data bits, 1 stop bit and no parity.

Can turbo speed be used for the tilt axis?

No, turbo speed is not allowed for the tilt axis; tilt speed ranges from 0x00 to 0x3F.