This manual is applicable to FECA-01 EtherCAT® adapter module, which provides Ethernet connectivity for ABB drives, converters and inverters.
This manual covers safety instructions, mechanical and electrical installation, start-up, communication profiles and protocol, diagnostics, technical data, and CoE object dictionaries for the ABB FECA-01 EtherCAT adapter module.
It includes configuration examples for ACS355, ACSM1, ACS850, ACS880 and ACS580 drives, plus master station configuration for an ABB AC500 PLC and Beckhoff TwinCAT.
| Degree of protection | IP20 |
|---|---|
| Power supply | +3.3 V +5%, max. 450 mA (supplied by the drive) |
| Connectors | 20-pin connector to the drive (X3); two 8P8C modular jacks (X1 and X2) |
| Indicators | Two green LEDs and one bicolor LED: LINK/ACT, LINK/ACT and STATUS |
| Installation | Into the option slot on the drive |
| Compatible devices | All EtherCAT-compliant devices |
| Medium | 100BASE-TX |
| Maximum segment length | 100 m |
| Topology | Daisy chain |
| Transfer rate | 100 Mbit/s |
| Serial communication type | Full duplex |
| Protocol | EtherCAT |
| EMC compliance | EN 61800-3:2004 |
The maximum segment length is 100 m.
It uses +3.3 V +5%, with a maximum current of 450 mA, supplied by the drive.
It has two green LEDs and one bicolor LED: LINK/ACT, LINK/ACT and STATUS.
The manual includes configuration examples for an ABB AC500 PLC and Beckhoff TwinCAT.