This manual provides information about Gold Line drives.
User Program Manual for Gold Line Drives, document MAN-G-USRPGM (Ver. 1.3), explains the Elmo language used with Elmo Gold servo drives. It describes setting up the drive, sending commands, querying drive status, direct communication by RS232 or CANopen, and user programs stored in the drive's non-volatile memory.
The manual covers command line syntax, expressions and operators, numbers, mathematical functions, variables, compiler directives, program flow commands, loops, and auto-routines. It also includes user program restrictions, limitations, and examples.
| Numerical types | 32-bit integers and 32-bit floating-point numbers |
|---|---|
| Integer range | –2,147,483,648 to +2,147,483,647 |
| Maximum expression length | 511 characters |
| Comment marker | Two consecutive asterisks (**) |
| Communication protocols | RS232, USB, TCP, EoE, CoE, CANopen |
Two methods can be used: direct communication and a user program.
A legal expression is limited to 511 characters.
Numbers containing a decimal point and numbers written in exponential notation are interpreted as floats.
A comment marker consists of two consecutive asterisks (**).