This manual describes the operation and use of the Guardmaster® 440G-LZ Safety Locking Switch, focusing on the switch's features and functions.
The Rockwell Automation Guardmaster 440G-LZ is a guard locking switch that extends a locking bolt through a hole in the actuator to prevent a guard from opening. RFID coding detects the appropriate actuator, and OSSD outputs are enabled only when the locking bolt is sensed in its extended position, with the guard closed and locked.
This user manual explains who should use the manual, installation and wiring, operation and LED diagnostics, troubleshooting, specifications, and typical installations. It also lists packaging contents, terminology, safety ratings, and catalog numbers.
| Standards | IEC 60947-5-3, IEC 60947-5-1, IEC 61508, EN/ISO 13849-1, IEC 62061, EN/ISO14119, UL 508 |
|---|---|
| Safety Classification | PLe Category 4 per ISO 13849-1, SIL 3 per IEC 61508 and IEC 62061 |
| Mission time/PTI | 20 years |
| Operating voltage Ue | 24V DC + 10% / -15% Class 2 SELV |
| Maximum output current (each output) | 200 mA |
| Holding force Fmax (EN/ISO 14119) | 1,690 N |
| Holding force Fzh (EN/ISO 14119) | 1,300 N |
| Protection class (IEC 61140) | Class II |
| Response time (Off) | 100 ms first switch, +50 ms for each additional switch |
It extends a locking bolt from the switch through a hole in the actuator to prevent the guard from opening. The locking bolt is allowed to extend only when the corresponding actuator is detected within range.
They are enabled only when the locking bolt is sensed in its extended position in the actuator, which occurs when the guard is closed and locked.
The box includes the switch body with connection lead, actuator mounting bracket, locking bolt, actuator, and QR code alignment guide.
The locking bolt drive uses a bi-stable solenoid, so the switch consumes very little electrical power and does not produce heat in either the locked or unlocked condition.