Rockwell Automation Guardmaster 440G-LZ Guard Locking Switch User Manual

This manual describes the operation and use of the Guardmaster® 440G-LZ Safety Locking Switch, focusing on the switch's features and functions.


Rockwell Automation Guardmaster 440G-LZ Guard Locking Switch User Manual - cover page
Brand
Rockwell Automation
Category
switch
Document type
User Manual
Language
English
Pages
39
File format
PDF
File size
11.7 MB
Published
01 November, 2023
Updated
01 November, 2023
MD5 checksum
5F70B8021747F1110356922497249B01

About this manual

The Rockwell Automation Guardmaster 440G-LZ is a guard locking switch that extends a locking bolt through a hole in the actuator to prevent a guard from opening. RFID coding detects the appropriate actuator, and OSSD outputs are enabled only when the locking bolt is sensed in its extended position, with the guard closed and locked.

This user manual explains who should use the manual, installation and wiring, operation and LED diagnostics, troubleshooting, specifications, and typical installations. It also lists packaging contents, terminology, safety ratings, and catalog numbers.

What's inside

  • Guardmaster 440G-LZ Overview
  • Safety Standards Applied to Guardmaster 440G-LZ
  • Installation and Wiring
  • Description of LEDs During Operation
  • Wiring with GSR Relay
  • Unit Response Times
  • Specifications
  • Typical Installations
  • EU Declaration of Conformity

Specifications

StandardsIEC 60947-5-3, IEC 60947-5-1, IEC 61508, EN/ISO 13849-1, IEC 62061, EN/ISO14119, UL 508
Safety ClassificationPLe Category 4 per ISO 13849-1, SIL 3 per IEC 61508 and IEC 62061
Mission time/PTI20 years
Operating voltage Ue24V DC + 10% / -15% Class 2 SELV
Maximum output current (each output)200 mA
Holding force Fmax (EN/ISO 14119)1,690 N
Holding force Fzh (EN/ISO 14119)1,300 N
Protection class (IEC 61140)Class II
Response time (Off)100 ms first switch, +50 ms for each additional switch

Frequently asked questions

What does the Guardmaster 440G-LZ guard locking switch do?

It extends a locking bolt from the switch through a hole in the actuator to prevent the guard from opening. The locking bolt is allowed to extend only when the corresponding actuator is detected within range.

When are the OSSD outputs enabled?

They are enabled only when the locking bolt is sensed in its extended position in the actuator, which occurs when the guard is closed and locked.

What is included with the switch?

The box includes the switch body with connection lead, actuator mounting bracket, locking bolt, actuator, and QR code alignment guide.

How is the locking bolt driven?

The locking bolt drive uses a bi-stable solenoid, so the switch consumes very little electrical power and does not produce heat in either the locked or unlocked condition.

Download PDF (11.7 MB)