This manual mainly introduces the product's functions and features, as well as installation methods
This document is an instruction manual for Patlite SKH-M series LED signal lights. It provides safety precautions, model number configuration, part names, mounting and installation dimensions, wiring, and specifications.
Covered items include terminal-block and cable-type installations, 2-point and 3-point hole mounting, 3-screw mounting, recommended lead-wire specifications, accessory quantities, and removal steps for terminal-block wiring.
| Rated voltage (M1 models) | 12 - 24 V DC (Non-polar) |
|---|---|
| Rated voltage (M2 models) | 100 - 240 V AC (50/60 Hz) |
| Recommended lead wire cross-section | 0.13 ~ 1.5 mm2 |
| Recommended lead wire gauge | AWG28 ~ 14 |
| Fuse rating | 250 V 1 A |
| Globe/case nominal diameter | Ø80 / Ø100 / Ø150 (SL only) |
| Maximum board thickness of mounting surface | 4.4 mm / 5.7 mm / 4.8 mm |
| Screw hole depth of mounting bracket | 9 mm / 8 mm / 10 mm |
| Nominal diameter of mounting screw | M4 / M5 / M8 |
M1 models are rated 12-24 V DC (non-polar), and M2 models are rated 100-240 V AC at 50/60 Hz.
Align a flathead screwdriver with the lever groove, press down to release the lock, then pull out the lead wire.
Use a soft cloth moistened with water; do not use thinner, benzine, gasoline, or oil.
No. The manual says not to perform blinking control by turning the power supply on or off for M2 models.