Matrix LDD-301-DI4-OP-S258 Photoelectric Distance Sensor Operating Manual

This manual describes the type LDD-301-DI4-OP-S258 photoelectric distance sensor. The sensor is manufactured by Radionic and meets IECEx and ATEX certification standards. It is suitable for use in Ex zones (0), 1, and 2 and has a maximum measurement range of 250 mm to 282 mm. The sensor also features high measurement accuracy, a visible red light laser, and a stainless steel 1.4404 housing.


Matrix LDD-301-DI4-OP-S258 Photoelectric Distance Sensor Operating Manual - cover page
Brand
Matrix
Category
sensor
Document type
User Manual
Language
English
Pages
2
File format
PDF
File size
41 KB
Published
31 October, 2023
Updated
31 October, 2023
MD5 checksum
199916E7B48E56E24BDC3DEB0DB7F1A1

About this manual

This document is the original operating manual for the Matrix LDD-301-DI4-OP-S258 photoelectric distance sensor, a time-of-flight sensor certified for use in explosive atmospheres. It provides technical data, electrical connection details, installation prescriptions, function description, and safety information.

The sensor provides an analog 4 mA to 20 mA current output and an RS-485 serial interface, with a START input for measurement control. The manual also covers maintenance, laser safety, conformity declarations, and mechanical dimensions.

What's inside

  • Technical data
  • Electrical connection
  • Maintenance and durability
  • Safety regulations for Laser devices class 2
  • General safety information
  • Intended use
  • Installation prescriptions for hazardous locations
  • General installation prescriptions
  • Function
  • Analog current output

Specifications

Measuring methodTime-of-flight measuring
Measurement range, analog output250 mm to 282 mm
Ex protectionGas, II 2(1)G Ex d [op is Ga] IIA T3 Gb
Ex zonesZones (0), 1, 2
Maximum optical radiant intensity<=1 mW, 620 nm to 690 nm
Maximum optical radiant power<=5 mW/mm2
Light sourceLaser Class 2 per EN 60825-1
Response time0.25 s to 4.5 s
Power-up delay time800 ms
Supply voltage24 VDC +/-10%
Maximum permissible voltage30 VDC
Current consumption70 mA
Maximum power dissipation2.4 W
Typical measurement tolerance+/-1 mm up to 10 m
Maximum measurement tolerance+/-2 mm up to 10 m
Distance-dependent tolerance increase<=0.15 mm/m
Analog current outputPNP, 4 mA to 20 mA, short-circuit protected
Analog output range250 mm to 282 mm (250 mm = 4 mA, 282 mm = 20 mA)
Analog error indication3.5 mA means invalid measurement
Analog output resolution1 mm = 0.5 mA
Analog load range500 ohm <= RL <= 1000 ohm
Serial interfaceRS-485, 9600 baud, 8 data bits, 1 stop bit, no parity, no handshaking
Serial interface range50 mm to 30 m
Serial interface resolution1 mm
START inputPNP compatible; H +24 VDC starts measurement, L 0 V stops measurement
HousingM42, stainless steel 1.4404
Enclosure ratingIP67
Ambient operating temperature-10 C to +35 C
Storage temperature-20 C to +70 C
Relative humidity15% to 80%
Connection cable5 m, PUR jacket, 6+PE x 0.5 mm2, shielded
Accessories2 nuts M42
OptionsCable length up to 100 m on request

Frequently asked questions

What is the measurement range of the analog output?

The analog output covers 250 mm to 282 mm.

What does an output current of 3.5 mA indicate?

It indicates that no valid measurement could be achieved.

How is a measurement started and stopped?

Apply +24 VDC to the START input to start measurement; connect it to 0 V to stop measurement.

What is the serial interface format?

The RS-485 interface uses 9600 baud, 8 data bits, 1 stop bit, no parity, and no handshaking.

Download PDF (41 KB)