Gardix USC Safety Light Barrier Technology Data

GARDIX Accident Prevention Light Barrier USL is a safety light barrier for accident prevention in dangerous areas. It belongs to safety category 4 and can also be used for applications in Ex-Zone 1 and 2. The system provides optimal alignment help via a state indicator in the receiver optics and has a high EMC level.


Gardix USC Safety Light Barrier Technology Data - cover page
Brand
Matrix
Category
Other
Document type
Datasheet
Language
English
Pages
2
File format
PDF
File size
41 KB
Published
19 March, 2012
Updated
30 September, 2023
MD5 checksum
552ED39B466B8F687BDDBCC4363270D1

About this manual

The Gardix USC safety light barrier is designed for accident prevention in hazardous areas, offering safety category 4 compliance and suitability for Ex‑Zones 1 and 2. It provides alignment assistance via state indication in the receiver optic and meets high EMC standards.

The document lists detailed electrical specifications, connection layouts for various controller types (USC‑S24, USC‑S24A, UDC‑S24A), and the required safety and regulatory approvals such as ATEX, PTB Ex‑83/1072, and EN standards.

What's inside

  • General
  • Specifications
  • Connection Layout
  • Safety Outputs
  • Ex‑Protection
  • Approvals
  • Installation Notes

Specifications

Supply Voltage24 VDC +/- 10%
Current Consumption330 mA (incl. Light Barriers)
Power Consumption9.24 W
Circuit Speed30 ms (worst time to switching off)
Safety Output Contacts1×NO + 1×NC (internal redundancy) / 2×NO + 2×NC
Maximum Load AC0.4 A at 250 VAC
Maximum Load DC3 A at U<40 VDC
Sensing Range10 m or 30 m
Minimum Object Size20 mm
Wavelength880 nm (Infrared)
Enclosure RatingIP20 (standard) / IP65 (Ex‑rated)

Frequently asked questions

What supply voltage does the Gardix USC safety light barrier require?

It operates from a 24 VDC supply with a tolerance of +/- 10 %.

What are the safety output contact configurations?

The device provides either 1 NO + 1 NC with internal redundancy or 2 NO + 2 NC contacts.

Which standards and approvals does the Gardix USC system meet?

It complies with ATEX, PTB Ex‑83/1072, EN 50100‑1, EN 954, EN 50014, EN 50018, EN 50081‑1/‑2, EN 50082‑1/‑2, EN 60825‑1 and other EU directives.

What is the maximum sensing range of the barrier?

The barrier can be configured for a sensing range of either 10 m or 30 m.

Download PDF (41 KB)