This is a quick installation guide for NextMove ESB-2. It contains very basic information about the mechanical and electrical installation of the NextMove ESB-2.
This guide contains very basic information about the mechanical and electrical installation of the NextMove ESB-2 and applies to all models with part numbers beginning NSB20... It includes safety instructions stating that all electrical installation and maintenance work should be carried out by qualified electricians only.
The guide covers mounting dimensions and weight, connector and wiring details, input power, stepper outputs, digital and analog I/O, encoder inputs, serial and CAN interfaces, and environmental limits. Start-up information is referred to the NextMove ESB-2 Motion Controller Installation Manual (MN1957WEN).
| Input power (nominal) | 24 V DC (±20%) |
|---|---|
| Power consumption | 50 W (2 A @ 24 V approx.) |
| Stepper output maximum frequency | 500 kHz |
| Encoder maximum input frequency | 10 MHz (quadrature) |
| Encoder supply | 5 V (±5%), 250 mA per encoder |
| Maximum encoder cable length | 30.5 m (100 ft) |
| Analog input common-mode voltage range | ±10 V DC |
| Analog input impedance | 120 kΩ |
| Analog input ADC resolution | 12 bits (includes sign bit) |
| Analog input equivalent resolution | ±4.9 mV (±10 V input) |
| Analog input sampling interval | 500 μs (both inputs enabled); 250 μs (one input disabled) |
| Relay contact rating | 1 A @ 24 V DC or 0.25 A @ 30 V AC |
| Relay operating time (max) | 5 ms |
| Analog output voltage range | ±10 V DC |
| Analog output current | 2.5 mA per output |
| Analog output DAC resolution | 12 bits |
| Analog output update interval | 100–2000 μs (default 1000) |
| Serial bit rates | 9600, 19200, 38400, 57600 (default), 115200 (RS232 only) |
| CAN bit rates (CANopen) | 10, 20, 50, 100, 125, 250, 500, 1000 kbit/s |
| Operating temperature range | 0 to +45 °C (+32 to +113 °F) |
| Maximum humidity | 80% up to 31 °C, decreasing to 50% at 45 °C, non-condensing |
| Maximum installation altitude | 2000 m (6560 ft) |
| Weight | Approximately 700 g (1.5 lb) |
| Terminal block tightening torque | 0.25 N·m (2.25 lbf-in) |
| USB communication | USB 1.1 |
It requires a 24 V DC power supply capable of supplying 2 A continuously.
It communicates using USB 1.1, or alternatively the RS232/RS485 serial port can be used.
The maximum ambient air temperature is 45 °C (113 °F) at rated current.