ABB NextMove ESB-2 Quick Installation Guide

This is a quick installation guide for NextMove ESB-2. It contains very basic information about the mechanical and electrical installation of the NextMove ESB-2.


ABB NextMove ESB-2 Quick Installation Guide - cover page
Brand
ABB
Category
Automation control Equipment
Document type
Installation Guide
Language
English
Pages
60
File format
PDF
File size
1.7 MB
Published
31 October, 2023
Updated
31 October, 2023
MD5 checksum
8DBE417D04638AE4E1EECFB435DF9878

About this manual

This guide contains very basic information about the mechanical and electrical installation of the NextMove ESB-2 and applies to all models with part numbers beginning NSB20... It includes safety instructions stating that all electrical installation and maintenance work should be carried out by qualified electricians only.

The guide covers mounting dimensions and weight, connector and wiring details, input power, stepper outputs, digital and analog I/O, encoder inputs, serial and CAN interfaces, and environmental limits. Start-up information is referred to the NextMove ESB-2 Motion Controller Installation Manual (MN1957WEN).

What's inside

  • About this guide
  • Mechanical installation
  • Connections
  • Input power (X1)
  • Stepper control outputs (X2, X3)
  • Digital outputs (X4, X11)
  • Encoder inputs (X5, X6, X7)
  • Digital inputs (X8, X9, X10)
  • Analog inputs and relay (X12)
  • Analog outputs (X13)

Specifications

Input power (nominal)24 V DC (±20%)
Power consumption50 W (2 A @ 24 V approx.)
Stepper output maximum frequency500 kHz
Encoder maximum input frequency10 MHz (quadrature)
Encoder supply5 V (±5%), 250 mA per encoder
Maximum encoder cable length30.5 m (100 ft)
Analog input common-mode voltage range±10 V DC
Analog input impedance120 kΩ
Analog input ADC resolution12 bits (includes sign bit)
Analog input equivalent resolution±4.9 mV (±10 V input)
Analog input sampling interval500 μs (both inputs enabled); 250 μs (one input disabled)
Relay contact rating1 A @ 24 V DC or 0.25 A @ 30 V AC
Relay operating time (max)5 ms
Analog output voltage range±10 V DC
Analog output current2.5 mA per output
Analog output DAC resolution12 bits
Analog output update interval100–2000 μs (default 1000)
Serial bit rates9600, 19200, 38400, 57600 (default), 115200 (RS232 only)
CAN bit rates (CANopen)10, 20, 50, 100, 125, 250, 500, 1000 kbit/s
Operating temperature range0 to +45 °C (+32 to +113 °F)
Maximum humidity80% up to 31 °C, decreasing to 50% at 45 °C, non-condensing
Maximum installation altitude2000 m (6560 ft)
WeightApproximately 700 g (1.5 lb)
Terminal block tightening torque0.25 N·m (2.25 lbf-in)
USB communicationUSB 1.1

Frequently asked questions

What power supply does the NextMove ESB-2 require?

It requires a 24 V DC power supply capable of supplying 2 A continuously.

How can the NextMove ESB-2 communicate with a host PC?

It communicates using USB 1.1, or alternatively the RS232/RS485 serial port can be used.

What is the maximum ambient air temperature?

The maximum ambient air temperature is 45 °C (113 °F) at rated current.

What is the weight of the controller?

The controller weighs approximately 700 g (1.5 lb).