Renishaw RGH/RGS20-S/RGS40-S Non-Contact Grating System Installation and Use Guide

This document details the installation and use of Renishaw's non-contact grating system, including the principle of the readout head, grating installation, and end clamp installation.


Renishaw RGH/RGS20-S/RGS40-S Non-Contact Grating System Installation and Use Guide - cover page
Brand
Renishaw
Category
sensor
Document type
Installation Guide
Language
Chinese
Pages
1
File format
PDF
File size
577 KB
Published
30 October, 2023
Updated
30 October, 2023
MD5 checksum
295C01F4C15A4B75777E524C2F114C65

About this manual

The document is a Chinese installation and use guide for the Renishaw non-contact grating system. It explains the RGH readhead principle: an infrared LED emits light onto the scale, reflected light passes through a transparent phase grating, and the readhead generates sinusoidal interference fringe signals; analog readheads output these signals directly, while digital readheads convert them into digital signals and output A/B square waves.

The guide then covers installation preparation, mounting and aligning the scale guide, loading the scale, adhering the scale along the travel, and fitting end clamps. It identifies RGA22G for RGH22/RGH26/RGH41 readheads and RGA245 for RGH24/RGH25 readheads, and notes a 40 mm allowance for end clamps. This manual is written in Chinese.

What's inside

  • RGH readhead technical principle
  • RGS20-S and RGS40-S scale installation
  • Installation preparation
  • Mounting the scale guide
  • Loading the scale into the scale guide
  • Installing the scale
  • End clamp installation

Specifications

Scale guide for RGH22, RGH26 and RGH41 readheadsRGA22G
Scale guide for RGH24 and RGH25 readheadsRGA245
End clamp modelA-9523-4015
AdhesiveA-9531-0342
End clamp allowance40 mm
Lacquer removal length15 mm

Frequently asked questions

How much scale length should be reserved for the end clamps?

Reserve 40 mm for installing the end clamps at the two ends of the scale.

Which scale guide is used with RGH24 and RGH25 readheads?

The RGA245 scale guide is designed for RGH24 and RGH25 readheads.

Can the A-9523-4015 end clamp be reused?

Yes. The document states that it can be installed on all Renishaw scale types and reused multiple times.

What should be done with excess adhesive around the end clamp?

Wipe away excess adhesive around the end clamp; otherwise the readhead signal may be affected.