Renishaw RGH/RGS20-S/RGS40-S Non-Contact Grating System Installation and Use Guide

Renishaw RGH/RGS20-S/RGS40-S Non-Contact Grating System Installation and Use Guide

Installation Guide 1 pages · 577 KB · ZH

The document is a Chinese installation and use guide for the Renishaw non-contact grating system. It explains the RGH readhead principle: an infrared LED emits light onto the scale, reflected light passes through a transparent phase grating, and the readhead generates sinusoidal interference fringe signals; analog readheads output these signals directly, while digital readheads convert them into digital signals and output A/B square waves.

The guide then covers installation preparation, mounting and aligning the scale guide, loading the scale, adhering the scale along the travel, and fitting end clamps. It identifies RGA22G for RGH22/RGH26/RGH41 readheads and RGA245 for RGH24/RGH25 readheads, and notes a 40 mm allowance for end clamps. This manual is written in Chinese.

Read online

Renishaw RGS40-S specifications

Scale guide for RGH22, RGH26 and RGH41 readheadsRGA22G
Scale guide for RGH24 and RGH25 readheadsRGA245
End clamp modelA-9523-4015
AdhesiveA-9531-0342
End clamp allowance40 mm
Lacquer removal length15 mm

Source: Renishaw RGH/RGS20-S/RGS40-S Non-Contact Grating System Installation and Use Guide

All Renishaw RGS40-S documents by type

Installation Guide 1

Mounting, wiring and first power-up. Read it before the hardware goes in.

Datasheet 1

Ratings, dimensions and ordering codes, for selection and design work.

Questions answered in these manuals

How much scale length should be reserved for the end clamps?

Reserve 40 mm for installing the end clamps at the two ends of the scale.

From: Renishaw RGH/RGS20-S/RGS40-S Non-Contact Grating System Installation and Use Guide

Which scale guide is used with RGH24 and RGH25 readheads?

The RGA245 scale guide is designed for RGH24 and RGH25 readheads.

From: Renishaw RGH/RGS20-S/RGS40-S Non-Contact Grating System Installation and Use Guide

What is the unit scale of the RGS20-S grating scale?

The RGS20-S grating scale has a unit scale of 20 µm.

From: Renishaw RGS20-S, RGS20-PC, RGS40-S, RGS40-PC Linear Encoder Specifications

What is the length range available for these grating scales?

The grating scales are available in lengths ranging from 100 mm to 50 m.

From: Renishaw RGS20-S, RGS20-PC, RGS40-S, RGS40-PC Linear Encoder Specifications