Installation guide for the Renishaw ATOM™ linear encoder system covering compliance, storage, installation steps, calibration and troubleshooting.
This guide provides detailed instructions for installing the ATOM™ high‑precision linear encoder system, including product compliance, storage conditions, and system‑level installation overview. It covers both RTLF steel‑tape and RCLC glass scales, application methods, and the use of reference fixtures and end caps.
The document also describes system connections, read‑head mounting and adjustment, calibration procedures, electrical wiring, output specifications, and a troubleshooting section to resolve common LED and signal issues. This manual is written in Chinese.
| RTLF scale material | hardened and quenched martensitic stainless steel |
|---|---|
| RTLF scale dimensions | 0.41 mm × 8 mm (H × W) |
| Power supply | 5 V ± 10 % |
| Operating temperature range | 0 °C to +70 °C |
| Storage temperature range | -20 °C to +70 °C |
| Cable type IP rating | IP40 |
| Maximum Ti interface cable length | 50 m |
The encoder requires a 5 V ± 10 % power supply.
The device can be stored from –20 °C to +70 °C.
Use adhesive stickers placed at 50 mm intervals to cancel unwanted reference zero positions.
The Ti interface supports cable lengths up to 50 m.