Technical datasheet for the Renishaw L-5913-8002-02-A C-ALS Cavity Auto-scanning Laser System, detailing specifications for laser modules, measuring ranges…
This document is a datasheet for the Renishaw L-5913-8002-02-A C-ALS Cavity Auto-scanning Laser System. It provides technical specifications including laser module details, measuring ranges, angle measurement accuracy, and physical data. The system utilizes an InGaAs laser diode with a typical wavelength of 905 nm and offers a maximum measuring range of up to 150 m against a passive target with 90% reflectivity.
| Laser type | InGaAs laser diode |
|---|---|
| Wavelength | 905 nm |
| Maximum range to a passive target | Up to 150 m |
| Minimum range | 0.5 m |
| Angle measurement accuracy | 0.2˚ |
| Angle measurement resolution | 0.1˚ |
| Vertical range | -90˚ to 90˚ |
| Horizontal range | 0˚ to 360˚ |
| Pitch-and-roll accuracy | ± 0.2˚ |
| Probe dimensions | 1100 mm × 50 mm |
| Surface unit dimensions | 270 mm × 245 mm × 170 mm |
| Probe weight | 5.9 kg |
| Surface unit weight | 4.1 kg |
| External power input | 12-15 V dc and 110-240 V ac |
The typical wavelength of the laser diode is 905 nm.
The maximum measuring range to a passive target is up to 150 m.
The vertical range is -90˚ to 90˚ and the horizontal range is 0˚ to 360˚.