The product is a controllable anti-pollution check valve that can be used in industrial, commercial and similar systems to prevent backflow, back pressure and back siphonage.
This product specification sheet covers the Honeywell RV281 controllable anti-pollution check valve, EA type with union connectors. It describes how the valve is built (brass housing, check valve insert, threaded or soldered union connectors, test and drain plugs, spring, disc with lip seal ring), lists the materials used and explains that the valve is intended as an independent means of preventing reverse water flow, typically installed directly after a water meter in central water supply systems, and as a safety device up to liquid category 2 of EN 1717.
Technical data is given for water as the medium, with an operating pressure of 16 bar, an opening pressure of approx. 0.05 bar and connection sizes from 1/2" to 2". The sheet also presents the method of operation of the spring-loaded check valve, the three connection options (A internal thread, B soldering, E external thread), a table of connection sizes, weights, dimensions and kvs-values, installation guidelines, typical applications, and a spare parts list with part numbers for the disc guide, spring, valve disc, hexagon plug and seal washer.
| Medium | Water, liquid category 2 (no hazardous material) |
|---|---|
| Operating pressure | 16 bar |
| Operating temperature | Water up to 65 °C (short term up to 90 °C), according to DIN EN 13959 |
| Opening pressure | approx. 0.05 bar |
| Connection size | 1/2" - 2" |
| Housing material | Brass |
| Lip seal ring material | EPDM |
| Spring material | Stainless steel |
| Test and drain plug thread | R 1/4" |
| kvs-value range | 4.5 to 60.0 m3/h |
| DIN/DVGW registration number | NW-6310 AT 2325 |
The operating pressure is 16 bar. The medium is water of liquid category 2 with no hazardous material.
The opening pressure is approximately 0.05 bar.
It can be installed in any position but is recommended in horizontal pipework with the test and drain plug downwards, right after a water meter if applicable, with shutoff valves for serviceability.