The GDQ33S12B module is a high efficiency, high power density 1/4 brick isolation module that can provide a rated output voltage of 12V and a maximum output current of 33A. The module's package size is 57.9mm×36.8mm×12.7mm (2.28inch×1.45inch×0.5inch).
The GDQ33S12B is a high-efficiency, high-power-density 1/4 brick isolated DC-DC power module designed for applications such as wireless, data, and network communication, servers, and workstations. It features a 36V to 72V input range and delivers 12V output at up to 33A. The module has a compact size of 57.9mm × 36.8mm × 12.7mm and includes protection features like undervoltage, overcurrent, short-circuit, and overvoltage protection with hiccup mode, as well as over-temperature protection with self-recovery. It meets UL60950-1, UL certification, EN55022 Class B, UL94V-0 flammability, and RoHS6 standards. This manual is written in Chinese.
| Input Voltage Range | 36V DC~72V DC |
|---|---|
| Output Voltage | 12V DC |
| Maximum Output Current | 33A |
| Efficiency | 95.6%@12V/33A |
| Dimensions | 57.9mm×36.8mm×12.7mm |
| Weight | 约 60g |
| Operating Temperature | -40℃ to 85℃ |
| Storage Temperature | -55℃ to 125℃ |
| Input Capacitance | 100uF to 220uF |
| Output Voltage Range | 11.64V to 12.36V (Vin=40V~72V) |
| Output Current | 0A to 33A |
| Output Ripple and Noise | 100mV to 250mV |
| Switching Frequency | 140kHz |
| MTBF | 1.5 million hours |
| Insulation Voltage | 1500V DC |
| Output Overcurrent Protection | 36A to 42A |
| Output Overvoltage Protection | 14V to 16V |
| Over-Temperature Protection Point | 115℃ to 125℃ |
| Output Voltage Rise Time | 40ms to 100ms |
| Output Voltage Turn-On Delay | 50ms |
The input voltage range is 36V DC to 72V DC.
The maximum output current is 33A.
The efficiency is 95.6% at 12V/33A.
The dimensions are 57.9mm × 36.8mm × 12.7mm.
The operating temperature range is -40℃ to 85℃.
The overcurrent protection point is 36A to 42A with hiccup mode.
The overvoltage protection point is 14V to 16V with hiccup mode.
The overtemperature protection point is 115℃ to 125℃ with self-recovery.
The output voltage rise time is 40ms to 100ms for 10% to 90% Vout.
The output voltage turn-on delay is 50ms.