This document is the user manual of using UCC3895 to control the direct current converter
The Texas Instruments UCC3895EVM-001 evaluation module is an isolated 48-V input phase-shifted full-bridge converter providing a 3.3-V output at 15 A. It uses the UCC3895 advanced phase-shift PWM controller in peak current-mode control for direct control driven synchronous rectification.
The user's guide provides the schematic, component list, assembly drawing, artwork and test setup needed to evaluate the UCC3895 in a typical control-driven synchronous rectification application. It also includes measured zero-voltage-switching waveforms and efficiency data.
| Input voltage | 48 V typical; 36 V to 72 V (2:1 range) |
|---|---|
| Output | 3.3 V at 15 A DC |
| Isolation | 1500 V input to output |
| Dimensions | 3.5 x 2.5 x 0.5 in |
| Oscillator frequency | 400 kHz; 200 kHz operating frequency |
| Efficiency | 87% |
| Control mode | Peak current-mode control |
| Protection | Short circuit protection |
It has a 48-V typical input with a 2:1 range from 36 V to 72 V.
It provides a 3.3-V output at 15 A DC.
OUTA and OUTB from the UCC3895 pass through signal transformer T3 and then drive U4, a UCC27424 dual 4-A MOSFET driver.
Efficiency is about 85% at 15 A, with peak efficiency just over 87% between 7 A and 10 A.