Newport SMC100CC & SMC100PP Single-Axis Motion Controller GUI Manual

This is a single-axis motion controller/driver for DC or stepper motor controller GUI manual


Newport SMC100CC & SMC100PP Single-Axis Motion Controller GUI Manual - cover page
Brand
Newport
Category
Motor
Document type
User Manual
Language
English
Pages
24
File format
PDF
File size
1.4 MB
Published
19 October, 2023
Updated
19 October, 2023
MD5 checksum
8CFEB2277029EBEEE81B65EA22073C53

About this manual

The SMC100CC & SMC100PP Controller GUI Manual explains how to use the SMC100 Controller GUI, a graphical user interface that lets the user interact with an SMC100CC or SMC100PP controller connected to stages. With it the user can initiate moves, change the state of the controller and adjust parameters. This edition is document EDH0310En1022, dated 11/13 and copyrighted 2013 by Newport Corporation.

The manual opens with an introduction, a controller state diagram with the meaning of each LED display, and instructions for building a system where up to 31 controllers are networked through the internal RS-485 link. It then covers discovering instruments and the user interface tabs — Configuration, Main, Jog, GPIO, Parameters, Address and Diagnostics — followed by an About tab and a service form.

What's inside

  • Introduction
  • Controller State Diagram
  • Building the System
  • Discover Instruments
  • Configuration
  • Jog
  • GPIO
  • Parameters
  • Address
  • Diagnostics

Specifications

Networked controllersUp to 31 controllers on the internal RS-485 link
Controller communication linkRS-485 (first controller on RS232 to the PC)
Maximum total power consumption of stages on one power supply80 W
Power chaining cableSMC-PSC0.2, supplied with the controller
Communication channel settingRS232

Frequently asked questions

How many SMC100 controllers can be networked together?

Up to 31 controllers can be networked through the internal RS-485 communication link, with the first one connected to the computer's RS232 connector at address #1.

How do I start the Controller GUI?

Start the Controller GUI from Newport\MotionControl\SMC100, then click the "Discover" button and select the com port where the instrument is connected.

What is the maximum power consumption allowed for stages on the same power supply?

The total power consumption of all stages connected to the same power supply should not exceed 80 W.

What is the Diagnostics tab used for?

The Diagnostics tab lets the user enter instrument commands and view the history of commands sent and responses received; a command file can be sent line by line.