The document is the instruction manual for the Anderson-Negele IZMAG electromagnetic flow meter, which mainly introduces the structure, function, technical parameters, use instructions and installation instructions of the product
The IZMAG Electromagnetic Flow Meter is a microprocessor-based device designed to measure the flow rate and volume of conductive liquids with high precision. It is available in integral and remote versions, operating on either AC or DC power supplies. The device features a transmitter with a meter tube and a converter that supplies regulated coil current and processes the signal generated at the electrodes.
| Supply voltage (DC) | 9 - 32 V DC |
|---|---|
| Supply voltage (AC) | 100 - 240 V AC, 50/60 Hz |
| Analog output | 0 or 4 - 20 mA |
| Digital input | 1 x galvanically isolated optocoupler input |
| Serial interface | RS485, CS3- Bus protocol |
| Ambient temperature (DC) | - 20°C ... +55°C |
| Minimum conductivity (integral) | 5 µS/cm |
| Minimum conductivity (remote) | 15 µS/cm |
The minimum conductivity required for the integral version is 5 µS/cm.
The maximum product temperature for the integral version is 100°C.
The instantaneous flow rate is output as an analog signal of 0 or 4...20 mA.