Anderson Instrument HB Series Mini Level Sensor User Manual

Introduces the specifications, performance and installation instructions of the HB series mini level sensor


Anderson Instrument HB Series Mini Level Sensor User Manual - cover page
Brand
Anderson Instrument
Document type
User Manual
Language
English
Pages
6
File format
PDF
File size
554 KB
Published
19 October, 2023
Updated
19 October, 2023
MD5 checksum
60165F667D36C7C683E1D757B6C24BAA

About this manual

This manual provides instructions for installing, wiring, and calibrating the HB Series Mini Level Sensor. It includes ordering matrices, environmental and electrical specifications, and step-by-step procedures for zero and span calibration using pressure simulators or product/water in the vessel. The sensor measures static head pressure in water column ranges from 0”-20” to 0”-160” and outputs a 4-20 mA signal. It is designed for sanitary applications and features a stainless steel sealed housing with NEMA 4X/IP-66, IP-67 ratings.

The manual also details wiring configurations, including M12 quick disconnect and conduit connector options, and specifies required power (12-40 VDC) and load impedance (1400 ohms max). Calibration adjustments are made via onboard potentiometers, with field calibration supported using known accurate pressure equipment or product/water in the vessel, with specific gravity corrections where needed.

What's inside

  • Ordering Matrix
  • Specifications
  • Description
  • Wiring
  • Zero Calibration
  • Calibration Ranges and Adjustments

Specifications

Operating Temperature Range40°F to 120°F (4°C to 49°C)
Output Signal4-20 mA DC, 2-wire
Power Voltage12-40 VDC
Load Impedance1400 ohms (max) @ 40 VDC
Housing Material304 Stainless Steel, Ra40 maximum finish
Wetted Parts Material316L Stainless Steel, Ra25 maximum finish
Process Connection2” Tri-Clamp
Environmental RatingNEMA 4X/IP-66, IP-67

Frequently asked questions

What is the output signal of the HB Series Mini Level Sensor?

The sensor outputs a 4-20 mA DC, 2-wire signal.

What is the power supply requirement?

The sensor requires 12-40 VDC loop power, with a recommended regulated supply below 24 VDC.